Filter
 Dimensions are shown for  reference only.                                                                                   
RADIUS POWER             www.radiuspower.com
Specifications are subject to change.                          Standard & Custom Products           PH 714-289-0055
                                                                                                                                    FAX 714-289-2149
                                                                                                     
Specifications
Operating Frequency:  DC - 60Hz
Operating Voltage: 480V +10%
Ambient Temperature: 50
oC
Inrush Rating:  20x (10ms), 1.5x (1min)
Climatic Category: 25/100/21
Hipot Rating: 3500VDC (P/N - E)
Terminations: 25A (M4), 50/55A (M5)
                        65/100A (M6), 150/200A (M10)
                        300A (M12), 500A (DUAL M12)
Safety Approval: UR/cUR/EN133200
Part Number / Ordering
RP300
-X
(Amps)
-Y
(Ycap, nF)
-T
25
0
S
50
.22
55
.47
65
1
100
2.2
150
3.3
200
4.7
300
10
500
22
100
1000
2200
Note: Use any –Y (Ycap) with any –X (Amps) rating
         e.g. RP300-500-2200-S
                   500 Amps with 2200nF y-caps
   
            
  
           
Leakage Current
Ycap, nF
mA, 400V/50HZ
0
0
.22
.004
.47
.009
1
.018
2.2
.04
3.3
.06
4.7
.09
10
.18
22
.4
100
1.8
1000
18
2200
30
Schematic
LINE                                                        LOAD
RP300
3PH DELTA TO 500A
ROHS COMPLIANT
RP300 Series                                  3-Phase Delta 1-Stage Power Line
 Dimensions are shown for  reference only.                                                                                   
RADIUS POWER             www.radiuspower.com
   Specifications are subject to change.                        Standard & Custom Products           PH 714-289-0055
                                                                                                                                    FAX 714-289-2149
                                                                                                     
25 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
75
75
75
60
50
DM, dB
60
75
75
68
50
50 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
65
75
70
55
50
DM, dB
50
75
75
75
65
55 / 65 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
55
70
70
65
45
DM, dB
65
75
75
75
50
100 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
70
75
75
60
50
DM, dB
50
75
75
60
55
150 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
50
70
60
48
40
DM, dB
50
75
70
45
45
200 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
48
70
60
48
40
DM, dB
50
75
70
45
45
300 / 500 AMP
FREQ(MHz)
.15
.5
1
10
30
CM, dB
60
50
50
45
40
DM, dB
50
45
45
40
30
          
                    
I
A
B
C
D
E
G
MTG
25
7.87
4.7
2.5
5.9
5.35
4.53
.25x.3
50
7.87
4.7
3.2
5.9
5.35
4.53
.25x.3
55/65
6.25
4.25
2.25
7.75
3.5
7
.2x.4
100
13
6.6
3.5
15.75
5.12
14.7
.3x.6
150
10
6.6
4.5
12
5.12
11
.3x.6
200/300
13
6.6
4.5
15.75
5.12
14.7
.3x.6
500
15
9.6
4.5
17
8
16
.3x.6
RP300 Typical Insertion Loss, 50/50ohm                 Mechanicals